您的位置:首页 > 其它

How to zone a Brocade SAN switch in command line base?

2014-06-03 08:45 417 查看
Here are the basics to add a new device to a Brocade SAN fabric. I’m working with a Brocade DCX switch. In this
scenario, there is a new server come with 2 HBA card that going to attach to the SAN switches.
Terminology
HBA -
Host Bus Adapter, HBA card is the device that connects the servers to a Storage Area Networks (SAN) via Fibre Channel.
 
WWN -
World Wide Name, a unique 8-byte number identifying the HBA. Each WWN is an 8-byte number derived from an IEEE OUI (for the first 3 bytes) and vendor-supplied information.

FC Zone - Fibre Channel Zone, a partitioned subset of the fabric. Members of a zone are allowed to communicate with
each other, but devices are not allowed to communicate across zones.
 
Steps to Zone Brocade Switch
 
Plug in the FC Connector into an open port on the switch.
Login to the server and verify the HBA connection. It should see the switch but not the storage device.
Check the Brocade Switch Port. To do so, telnet to the brocade switches and login as user admin.
            switch 1 - fabric A (SWITCH_1) 

            switch 2 - fabric B (SWITCH_2)
             Create aliases for the hosts HBA's on each switch
             Example:
            switch_1> alicreate " HOSTNAME01_HBA_0","10:00:00:c9:69:3d:53" 

            switch_2> alicreate " HOSTNAME01_HBA_1","10:00:00:c9:69:ae:4e"
      Tips: Do a switchshow to capture the WWN before start the aliases creation.
 
Create the storage zones using the aliases on each switch
            switch_1> zonecreate "Z_HOSTNAME01_A", "HOSTNAME01_HBA_0"

            switch_2> zonecreate "Z_HOSTNAME01_B", "HOSTNAME01_HBA_1"
            Check the configuration

            switch_1> zoneshow Z_HOSTNAME01_A

            switch_2> zoneshow Z_HOST01_B
 
Add the zones to the fabrics on each switch
            switch_1> cfgshow SWITCH_A 

            switch_1> cfgadd "SWITCH_A","Z_ HOSTNAME01_A"

            switch_1> cfgsave

            switch_1> cfgenable SWITCH_A

            Check the configuration

            switch_1> zoneshow
            switch_2> cfgshow SWITCH_B

            switch_2> cfgadd " SWITCH_B","Z_ HOSTNAME01_B"

            switch_2> cfgsave

            switch_2> cfgenable SWITCH_A
             Check the configuration
             switch_2> zoneshow
 
Login back in to the server to verify. It should now see the storage devices