IAR Build from the command line 环境变量设置
2013-12-31 08:59
836 查看
http://supp.iar.com/Support/?Note=47884
Technical Note 47884
Alternative 1 - run IarBuild.exe from the command line
If you have a project file named test.ewp with a configuration named Debug , the following command line can be used to build the project:
Note: run IarBuild.exe without parameters to get Usage information
To re-build use the following command line (extended with an option to get logging of all compiler messages):
... which corresponds to ...
Alternative 2 - run compiler and linker from the command line
You can run all .exe files in the (EWARM installation)\arm\bin folder from the command line. Run each of them, e.g. iccarm.exe, without parameters to get a list of available command line options.
You can make a .bat file that compiles each source file one-by-one if you know the command line parameters.
To see the command line parameters, enable the option IAR Embedded Workbench IDE > Tools > Options... > IDE Options > Messages > Show build messages > select 'All'.
To make a .bat file compiling one source file, enter the full path to iccarm.exe followed by the parameters (copy from the build window) using the format:
When you get the command line working for one source file, you can add more command lines for the remaining source files.
If you want to invoke ilinkarm too, you can use the option -f <file> , for example
and in the file options.xcl put all the parameters from the build window (put the parameters on separate lines).
IAR_ARM_WORKBENCH_PATH : C:\Program Files (x86)\IAR Systems\Embedded Workbench xxxx
IAR_COMMON_PATH : %IAR_ARM_WORKBENCH_PATH%\common\bin
IAR_TOOLCHAIN_PATH : %IAR_ARM_WORKBENCH_PATH%\arm\bin
Path : %IAR_COMMON_PATH%;%IAR_TOOLCHAIN_PATH%; .........
Technical Note 47884
Build from the command line
The alternatives below are exemplified for Embedded Workbench for ARM (EWARM), but can be easily be modified for another EW target.This Technical Note might be helpful if you are looking for way to build your project outside the Embedded Workbench.Alternative 1 - run IarBuild.exe from the command line
If you have a project file named test.ewp with a configuration named Debug , the following command line can be used to build the project:
(EWARM installation)\common\bin\IarBuild.exe test.ewp Debug
Note: run IarBuild.exe without parameters to get Usage information
To re-build use the following command line (extended with an option to get logging of all compiler messages):
(EWARM installation)\common\bin\IarBuild.exe test.ewp -build Debug -log all
... which corresponds to ...
(EWARM installation)\common\bin\IarBuild.exe test.ewp -clean Debug -log all (EWARM installation)\common\bin\IarBuild.exe test.ewp -make Debug -log all
Alternative 2 - run compiler and linker from the command line
You can run all .exe files in the (EWARM installation)\arm\bin folder from the command line. Run each of them, e.g. iccarm.exe, without parameters to get a list of available command line options.
You can make a .bat file that compiles each source file one-by-one if you know the command line parameters.
To see the command line parameters, enable the option IAR Embedded Workbench IDE > Tools > Options... > IDE Options > Messages > Show build messages > select 'All'.
To make a .bat file compiling one source file, enter the full path to iccarm.exe followed by the parameters (copy from the build window) using the format:
(EWARM installation)\arm\bin\iccarm.exe <source-file> <options>
When you get the command line working for one source file, you can add more command lines for the remaining source files.
If you want to invoke ilinkarm too, you can use the option -f <file> , for example
(EWARM installation)\arm\bin\ilinkarm.exe -f options.xcl
and in the file options.xcl put all the parameters from the build window (put the parameters on separate lines).
IAR_ARM_WORKBENCH_PATH : C:\Program Files (x86)\IAR Systems\Embedded Workbench xxxx
IAR_COMMON_PATH : %IAR_ARM_WORKBENCH_PATH%\common\bin
IAR_TOOLCHAIN_PATH : %IAR_ARM_WORKBENCH_PATH%\arm\bin
Path : %IAR_COMMON_PATH%;%IAR_TOOLCHAIN_PATH%; .........
相关文章推荐
- myPid() 和 myUid() 的区别
- Geeksforgeeks面试题 - Longest Increasing Subsequence
- 10个必备的移动UI设计资源站(转)
- UIAlertView用block方式代替delegate
- UIWindow的一点儿思考
- common.h:178:47: error: 'UINT64_C' was not declared in this scope
- UITabBarController
- 第十二章:表视图常用UI范例——下拉刷新+无限滚动
- 123 - Searching Quickly
- Form Builder开发中可视属性集(Visual Attributes)
- [css layout][18]Liquid, secondary columns fixed-width
- URL Loading System Programing Guide (2)
- break -- continue
- [Android] Android开发优化之——对界面UI的优化(3)
- Easyui 项目展示
- Build kernel
- LeetCode Permutation Sequence
- Chapter 3 | Stacks and Queues--一个数组实现三个栈
- MFC中用户界面元素更新原理(UPDATE_COMMAND_UI)
- sharepoint 2013 "The module ... owssvr.dll could not be loaded due to a configuration problem"