型号:思科CRS-1    系统版本:IOS XR , Version 4.0.4

CRS-1#show controllers SONET 0/0/1/0
<…>

Optical Power Monitoring (accuracy: +/- 1dB)
Rx power = 0.0828 mW, -10.8 dBm
Tx power = 1.0288 mW, 0.1 dBm
Tx laser current bias = 68.3 mA

!<---------POS口


 

CRS-1#show hw-module subslot 0/10/0 status pluggable-optics 0
SPA 0/10/0 device pluggable-optics 0/0 info:
int Tengige/10/0/0:
State: Enabled
Environmental Information - raw values
Temperature: 8602
Tx voltage: 0 in units of 100uVolt
Tx bias: 63000 uA
Tx power: 0 dBm (10180 in units of 0.1 uW)
Rx power: -9 dBm (1126 in units of 0.1 uW)
(AUX1) +3.3V Supply Voltage: 32324
!<---------GE口


 

型号:思科7609

7609#show interfaces te1/1 transceiver
Optical   Optical
Temperature  Voltage  Current   Tx Power  Rx Power
Port        (Celsius)    (Volts)  (mA)      (dBm)     (dBm)
----------  -----------  -------  --------  --------  --------
Te1/1         40.3        N/A      83.6 --    1.9     -14.3


 

型号:思科Nexus7010

N7K#show interface e3/1 transceiver details

SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current              Alarms                  Warnings
Measurement     High        Low         High          Low
----------------------------------------------------------------------------
Temperature   24.08 C        90.00 C    -10.00 C     85.00 C       -5.00 C
Voltage        3.27 V         3.59 V      3.00 V      3.50 V        3.09 V
Current        6.79 mA       15.00 mA     1.00 mA    12.00 mA       2.00 mA
Tx Power      15.03 dBm      20.00 dBm    6.50 dBm   17.00 dBm     10.49 dBm
Rx Power      12.35 dBm      23.00 dBm   -1.02 dBm   20.00 dBm      3.01 dBm


型号:华为NE5000E

NE5000E#display interface pos 1/6/0/0
<…>
Rx Optical Power: -3.62dBm, Tx Optical Power: -2.25dBm
Physical layer is Packet Over SDH
Scramble enabled, clock master, CRC-32, loopback: none
Flag J0 "NetEngine       "
Flag J1 "NetEngine       "
Flag C2 22(0x16)
SDH alarm:
section layer:  none
line    layer:  none
path    layer:  none
SDH error:
section layer:  B1 0
line    layer:  B2 0  REI 0
path    layer:  B3 0  REI 0
<…>
!<---------POS口


NE5000E#display interface gi1/8/0/1
<..>
WaveLength: 1310nm, Transmission Distance: 10km
Rx Optical Power: -5.06dBm, Tx Optical Power: -2.01dBm
Loopback:none, LAN full-duplex mode, Pause Flowcontrol:Receive Enable and Send Enable
<..>
!<-------GE口


 

型号:华为9312

S9312#display transceiver interface XGigabitEthernet 1/1/0/0 verbose
<…>
-------------------------------------------------------------
Diagnostic information:
Temperature(¡ãC)                      :35
Voltage(V)                            :3.31
Bias Current(mA)                      :6.52
Bias High Threshold(mA)               :10.00
Bias Low  Threshold(mA)               :2.60
Current Rx Power(dBM)                 :-3.12
Default Rx Power High Threshold(dBM)  :1.50
Default Rx Power Low  Threshold(dBM)  :-14.00
Current Tx Power(dBM)                 :-2.10
Default Tx Power High Threshold(dBM)  :-1.00
Default Tx Power Low  Threshold(dBM)  :-8.00
User Set Rx Power High Threshold(dBM) :1.50
User Set Rx Power Low Threshold(dBM)  :-14.00
User Set Tx Power High Threshold(dBM) :-1.00
User Set Tx Power Low Threshold(dBM)  :-8.00
-------------------------------------------------------------


 

型号:华为8512

S8512#display fiber-module GigabitEthernet 0/1/1
GigabitEthernet0/1/1 transceiver information:
Transceiver Type                   : 10G_LR_SM_LC
Connector Type                     : LC
Wavelength(nm)                     : 1310
Transfer Distance                  : 10km(SMF)
Digital Diagnostic Monitoring      : YES
Vendor Name                        : FINISAR CORP.
TX Power                           : -2.0dBM
RX Power                           : -2.5dBM


 

 

型号:H3C  12508

H3C12508#display transceiver diagnosis interface te3/0/1
Ten-GigabitEthernet3/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(°C) Voltage(V)  Bias(mA)  RX power(dBM)  TX power(dBM)
30         3.36        30.10     -1.45          -2.01


 

型号:Juniper EX8208

EX8208>show interfaces diagnostics optics xe-0/0/1
Physical interface: xe-0/0/1
Laser bias current                        :  37.996 mA
Laser output power                        :  0.6900 mW / -1.61 dBm
Module temperature                        :  30 degrees C / 86 degrees F
Module voltage                            :  3.2990 V
Receiver signal average optical power     :  0.5150 mW / -2.88 dBm
<…>


 

型号:中兴8905     系统版本:V3.00.02.B10

ZXR10(config)#interface xgei-0/1/0/2

ZXR10(config-if)#optical-inform monitor enable

ZXR10#show optical-inform brief interface xgei-0/1/0/2
If device is externally calibrated, only calibrated values are printed.
-Inf: not applicable, Tx: transmit, Rx: receive.
Optical   Optical
Interface     Temperature  Voltage  Voltage    Current   Tx Power  Rx Power
Name          (Celsius)  (3.3 Volts)(5 Volts)  (mA)      (dBm)     (dBm)
--------------------------------------------------------------------------------
xgei-0/1/0/2   33.20       3.27      N/A       54.01     1.87      -10.72


 

型号:上海贝尔Omniswitch 10K

OS10K>interfaces ddm enable

OS10K>show interfaces port 3/1 ddm
Slot/     Thres-    Temp       Voltage      Tx Bias      Output       Input
Port      hold       (C)         (V)          (mA)        (dBm)       (dBm)
----------+--------+----------+------------+------------+------------+------------
3/1       Actual    21.0        3.258        4.136       -5.969       -6.719
A-High   100.0        3.600       40.000        1.000        3.486
W-High    90.0        3.500       30.000        0.000        2.486
W-Low      0.0        3.100        1.000       -9.500      -12.518
A-Low     -5.0        3.000        0.500      -10.501      -13.516


 

型号:阿尔卡特(贝尔)SR 7750

SR7750#show port 1/1/1 detail | match DDM post-lines 10
Last Cleared Time  : 10/25/2012 15:54:54        DDM Events       : Enabled
Configured Mode    : network                    Encap Type       : null
Dot1Q Ethertype    : 0x8100                     QinQ Ethertype   : 0x8100
PBB Ethertype      : 0x88e7
Ing. Pool % Rate   : 100                        Egr. Pool % Rate : 100
Ing. Pool Policy   : n/a
Egr. Pool Policy   : n/a
Net. Egr. Queue Pol: default
Egr. Sched. Pol    : n/a
Auto-negotiate     : N/A                        MDI/MDX          : N/A
Transceiver Digital Diagnostic Monitoring (DDM)
===============================================================================
Value High Alarm  High Warn   Low Warn  Low Alarm
-------------------------------------------------------------------------------
Temperature (C)               +28.8     +83.0      +80.0      -10.0     -13.0
Tx Bias Current (mA)           37.9      80.0       75.0       20.0      15.0
Tx Output Power (dBm)         -1.97      1.50       1.00      -6.00     -7.00
Rx Optical Power (avg dBm)    -3.11      2.50       2.00     -18.01    -20.00
Aux1: 3.3 Voltage (V)          3.29      3.63       3.50       3.10      3.00
===============================================================================